Molded Case Circuit Breaker BM Series

Molded Case Circuit Breaker With Rated Current:3-1600A

Shihlin Electric BM series molded case circuit breaker are for overload and short circuit protection

Protection

  • Overload portection
  • Short circuit pretection

BM30-CN

Rated current: 3, 5, 10, 15, 20, 30A

Specification

Hydraulic magnetic
Standard: IEC60947-2
Rated current: 3, 5, 10, 15, 20, 30A
Pole: 2P, 3P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 380V : 2P, 3P =1.5
       lcu(kA) : 220V (240V) : 2P, 3P =2.5

BM30-SN

Rated current: 3, 5, 10, 15, 20, 30A

Specification

Hydraulic magnetic
Standard: IEC60947-2
Rated current: 3, 5, 10, 15, 20, 30A
Pole: 2P, 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 2P, 3P =1.5
       lcu(kA) : 4400V (240V) : 2P, 3P =2.5
       lcu(kA) : 380V : 2P, 3P =2.5
       lcu(kA) : 220V (240V) : 2P, 3P =5

BM50-CN

Rated current: 10, 15, 20, 30, 40, 50A

Specification

Hydraulic magnetic
Standard: IEC60947-2
Rated current: 10, 15, 20, 30, 40, 50A
Pole: 2P, 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 2P, 3P =1.5
       lcu(kA) : 4400V (240V) : 2P, 3P =2.5
       lcu(kA) : 380V : 2P, 3P =2.5
       lcu(kA) : 220V (240V) : 2P, 3P =5

BM60-SN

Rated current: 10, 15, 20, 30, 40, 50, 60A

Specification

Hydraulic magnetic
Standard: IEC60947-2
Rated current: 10, 15, 20, 30, 40, 50, 60A
Pole: 2P, 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 2P, 3P, 4P =5
       lcu(kA) : 4400V (240V) : 2P, 3P, 4P =7.5
       lcu(kA) : 380V : 2P, 3P, 4P =7.5
       lcu(kA) : 220V (240V) : 2P, 3P, 4P =10

BM60-HN

Rated current: 10, 15, 20, 30, 40, 50, 60A

Specification

Hydraulic magnetic
Standard: IEC60947-2
Rated current: 10, 15, 20, 30, 40, 50, 60A
Pole: 2P, 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 2P, 3P, 4P =5
       lcu(kA) : 4400V (240V) : 2P, 3P, 4P =10
       lcu(kA) : 380V : 2P, 3P, 4P =15
       lcu(kA) : 220V (240V) : 2P, 3P, 4P =25

BM60-HBN

Rated current: 10, 15, 20, 30, 40, 50, 60A

Specification

Hydraulic magnetic
Standard: IEC60947-2
Rated current: 10, 15, 20, 30, 40, 50, 60A
Pole: 2P, 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 3P =5
       lcu(kA) : 4400V (240V) : 3P =10
       lcu(kA) : 380V : 3P =15
       lcu(kA) : 220V (240V) : 3P =50

BM100-MN

Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100A

Specification

Hydraulic magnetic
Standard: IEC60947-2
Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100A
Pole: 2P, 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 2P, 3P =5
       lcu(kA) : 4400V (240V) : 2P, 3P =7.5
       lcu(kA) : 380V : 2P, 3P =10
       lcu(kA) : 220V (240V) : 2P, 3P =15

BM100-SN

Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100A

Specification

Hydraulic magnetic
Standard: IEC60947-2
Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100A
Pole: 2P, 3P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 2P, 3P =5
       lcu(kA) : 4400V (240V) : 2P, 3P =10
       lcu(kA) : 380V : 2P, 3P =15
       lcu(kA) : 220V (240V) : 2P, 3P =25

BM100-HN

Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100A

Specification

Hydraulic magnetic
Standard: IEC60947-2
Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100A
Pole: 2P, 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 2P, 3P, 4P =15
       lcu(kA) : 4400V (240V) : 2P, 3P, 4P =25
       lcu(kA) : 380V : 2P, 3P, 4P =30
       lcu(kA) : 220V (240V) : 2P, 3P, 4P =50

BM100-HBN

Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100A

Specification

Adj. thermal / Fixed magnetic
Standard: IEC60947-2
Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100A
Pole: 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 3P, 4P =20
       lcu(kA) : 4400V (240V) : 3P, 4P =32
       lcu(kA) : 380V : 3P, 4P =36
       lcu(kA) : 220V (240V) : 3P, 4P =85

BM100-H

Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100A

Specification

Thermal magnetic
Standard: IEC60947-2
Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100A
Pole: 3P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 3P, 4P =25
       lcu(kA) : 4400V (240V) : 3P, 4P =42
       lcu(kA) : 380V : 3P, 4P =50
       lcu(kA) : 220V (240V) : 3P, 4P =85

BM100-HC

Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100A

Specification

Thermal magnetic
Standard: IEC60947-2
Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100A
Pole: 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 3P, 4P =42
       lcu(kA) : 4400V (240V) : 3P, 4P =55
       lcu(kA) : 380V : 3P, 4P =70
       lcu(kA) : 220V (240V) : 3P, 4P =100

BM100-HS

Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100A

Specification

Thermal magnetic
Standard: IEC60947-2
Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100A
Pole: 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 3P, 4P =50
       lcu(kA) : 4400V (240V) : 3P, 4P =70
       lcu(kA) : 380V : 3P, 4P =85
       lcu(kA) : 220V (240V) : 3P, 4P =125

BM125-SN

Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100, 125A

Specification

Hydraulic magnetic
Standard: IEC60947-2
Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100, 125A
Pole: 2P, 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 2P, 3P, 4P =7.5
       lcu(kA) : 4400V (240V) : 2P, 3P, 4P =15
       lcu(kA) : 380V : 2P, 3P, 4P =22
       lcu(kA) : 220V (240V) : 2P, 3P, 4P =30

BM125-HN

Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100, 125A

Specification

Hydraulic magnetic
Standard: IEC60947-2
Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100, 125A
Pole: 2P, 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 2P, 3P, 4P =15
       lcu(kA) : 4400V (240V) : 2P, 3P, 4P =25
       lcu(kA) : 380V : 2P, 3P, 4P =30
       lcu(kA) : 220V (240V) : 2P, 3P, 4P =50

BM160-SN

Rated current: 125, 140, 160A

Specification

Adj. thermal / Fixed magnetic
Standard: IEC60947-2
Rated current: 125, 140, 160A
Pole: 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 2P, 3P, 4P =15
       lcu(kA) : 4400V (240V) : 2P, 3P, 4P =25
       lcu(kA) : 380V : 2P, 3P, 4P =30
       lcu(kA) : 220V (240V) : 2P, 3P, 4P =50

BM160-HN

Rated current: 125, 140, 160A

Specification

Adj. thermal / Fixed magnetic
Standard: IEC60947-2
Rated current: 125, 140, 160A
Pole: 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 3P, 4P =20
       lcu(kA) : 4400V (240V) : 3P, 4P =32
       lcu(kA) : 380V : 3P, 4P =36
       lcu(kA) : 220V (240V) : 3P, 4P =85

BM160-HฺB

Rated current: 125, 140, 160A

Specification

Thermal magnetic
Standard: IEC60947-2
Rated current: 125, 140, 160A
Pole: 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 3P, 4P =25
       lcu(kA) : 4400V (240V) : 3P, 4P =42
       lcu(kA) : 380V : 3P, 4P =50
       lcu(kA) : 220V (240V) : 3P, 4P =85

BM160-HฺC

Rated current: 125, 140, 160A

Specification

Thermal magnetic
Standard: IEC60947-2
Rated current: 125, 140, 160A
Pole: 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 3P, 4P =42
       lcu(kA) : 4400V (240V) : 3P, 4P =55
       lcu(kA) : 380V : 3P, 4P =70
       lcu(kA) : 220V (240V) : 3P, 4P =100

BM160-HฺS

Rated current: 125, 140, 160A

Specification

Thermal magnetic
Standard: IEC60947-2
Rated current: 125, 140, 160A
Pole: 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 3P, 4P =50
       lcu(kA) : 4400V (240V) : 3P, 4P =70
       lcu(kA) : 380V : 3P, 4P =85
       lcu(kA) : 220V (240V) : 3P, 4P =125

BM250-CN

Rated current: 125, 150, 175, 200, 225, 250A

Specification

Adj. thermal / Fixed magnetic
Standard: IEC60947-2
Rated current: 125, 140, 160A
Pole: 2P, 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 2P, 3P, 4P =7.5
       lcu(kA) : 4400V (240V) : 2P, 3P, 4P =15
       lcu(kA) : 380V : 2P, 3P, 4P =22
       lcu(kA) : 220V (240V) : 2P, 3P, 4P =30

BM250-SN

Rated current: 125, 150, 175, 200, 225, 250A

Specification

Adj. thermal / Fixed magnetic
Standard: IEC60947-2
Rated current: 125, 140, 160A
Pole: 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 2P, 3P, 4P =
       lcu(kA) : 4400V (240V) : 2P, 3P, 4P =
       lcu(kA) : 380V : 2P, 3P, 4P =
       lcu(kA) : 220V (240V) : 2P, 3P, 4P =

BM250-HN

Rated current: 125, 150, 175, 200, 225, 250A

Specification

Adj. thermal / Fixed magnetic
Standard: IEC60947-2
Rated current: 125, 140, 160A
Pole: 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 2P, 3P, 4P =
       lcu(kA) : 4400V (240V) : 2P, 3P, 4P =
       lcu(kA) : 380V : 2P, 3P, 4P =
       lcu(kA) : 220V (240V) : 2P, 3P, 4P =

BM250-HB

Rated current: 125, 150, 175, 200, 225, 250A

Specification

Adj. thermal / Fixed magnetic
Standard: IEC60947-2
Rated current: 125, 140, 160A
Pole: 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 2P, 3P, 4P = 25
       lcu(kA) : 4400V (240V) : 2P, 3P, 4P = 42
       lcu(kA) : 380V : 2P, 3P, 4P = 50
       lcu(kA) : 220V (240V) : 2P, 3P, 4P = 85

By clicking “Accept”, you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts. Privacy Policy

Privacy Preferences

Allow All
Manage Consent Preferences
  • Always Active

Save