Molded Case Circuit Breaker BM Series

Molded Case Circuit Breaker With Rated Current:3-1600A

Shihlin Electric BM series molded case circuit breaker are for overload and short circuit protection

Protection

  • Overload portection
  • Short circuit pretection

BM30-CN

Rated current: 3, 5, 10, 15, 20, 30A

Specification

Hydraulic magnetic
Standard: IEC60947-2
Rated current: 3, 5, 10, 15, 20, 30A
Pole: 2P, 3P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 380V : 2P, 3P =1.5
       lcu(kA) : 220V (240V) : 2P, 3P =2.5

BM30-SN

Rated current: 3, 5, 10, 15, 20, 30A

Specification

Hydraulic magnetic
Standard: IEC60947-2
Rated current: 3, 5, 10, 15, 20, 30A
Pole: 2P, 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 2P, 3P =1.5
       lcu(kA) : 4400V (240V) : 2P, 3P =2.5
       lcu(kA) : 380V : 2P, 3P =2.5
       lcu(kA) : 220V (240V) : 2P, 3P =5

BM50-CN

Rated current: 10, 15, 20, 30, 40, 50A

Specification

Hydraulic magnetic
Standard: IEC60947-2
Rated current: 10, 15, 20, 30, 40, 50A
Pole: 2P, 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 2P, 3P =1.5
       lcu(kA) : 4400V (240V) : 2P, 3P =2.5
       lcu(kA) : 380V : 2P, 3P =2.5
       lcu(kA) : 220V (240V) : 2P, 3P =5

BM60-SN

Rated current: 10, 15, 20, 30, 40, 50, 60A

Specification

Hydraulic magnetic
Standard: IEC60947-2
Rated current: 10, 15, 20, 30, 40, 50, 60A
Pole: 2P, 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 2P, 3P, 4P =5
       lcu(kA) : 4400V (240V) : 2P, 3P, 4P =7.5
       lcu(kA) : 380V : 2P, 3P, 4P =7.5
       lcu(kA) : 220V (240V) : 2P, 3P, 4P =10

BM60-HN

Rated current: 10, 15, 20, 30, 40, 50, 60A

Specification

Hydraulic magnetic
Standard: IEC60947-2
Rated current: 10, 15, 20, 30, 40, 50, 60A
Pole: 2P, 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 2P, 3P, 4P =5
       lcu(kA) : 4400V (240V) : 2P, 3P, 4P =10
       lcu(kA) : 380V : 2P, 3P, 4P =15
       lcu(kA) : 220V (240V) : 2P, 3P, 4P =25

BM60-HBN

Rated current: 10, 15, 20, 30, 40, 50, 60A

Specification

Hydraulic magnetic
Standard: IEC60947-2
Rated current: 10, 15, 20, 30, 40, 50, 60A
Pole: 2P, 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 3P =5
       lcu(kA) : 4400V (240V) : 3P =10
       lcu(kA) : 380V : 3P =15
       lcu(kA) : 220V (240V) : 3P =50

BM100-MN

Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100A

Specification

Hydraulic magnetic
Standard: IEC60947-2
Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100A
Pole: 2P, 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 2P, 3P =5
       lcu(kA) : 4400V (240V) : 2P, 3P =7.5
       lcu(kA) : 380V : 2P, 3P =10
       lcu(kA) : 220V (240V) : 2P, 3P =15

BM100-SN

Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100A

Specification

Hydraulic magnetic
Standard: IEC60947-2
Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100A
Pole: 2P, 3P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 2P, 3P =5
       lcu(kA) : 4400V (240V) : 2P, 3P =10
       lcu(kA) : 380V : 2P, 3P =15
       lcu(kA) : 220V (240V) : 2P, 3P =25

BM100-HN

Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100A

Specification

Hydraulic magnetic
Standard: IEC60947-2
Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100A
Pole: 2P, 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 2P, 3P, 4P =15
       lcu(kA) : 4400V (240V) : 2P, 3P, 4P =25
       lcu(kA) : 380V : 2P, 3P, 4P =30
       lcu(kA) : 220V (240V) : 2P, 3P, 4P =50

BM100-HBN

Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100A

Specification

Adj. thermal / Fixed magnetic
Standard: IEC60947-2
Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100A
Pole: 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 3P, 4P =20
       lcu(kA) : 4400V (240V) : 3P, 4P =32
       lcu(kA) : 380V : 3P, 4P =36
       lcu(kA) : 220V (240V) : 3P, 4P =85

BM100-H

Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100A

Specification

Thermal magnetic
Standard: IEC60947-2
Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100A
Pole: 3P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 3P, 4P =25
       lcu(kA) : 4400V (240V) : 3P, 4P =42
       lcu(kA) : 380V : 3P, 4P =50
       lcu(kA) : 220V (240V) : 3P, 4P =85

BM100-HC

Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100A

Specification

Thermal magnetic
Standard: IEC60947-2
Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100A
Pole: 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 3P, 4P =42
       lcu(kA) : 4400V (240V) : 3P, 4P =55
       lcu(kA) : 380V : 3P, 4P =70
       lcu(kA) : 220V (240V) : 3P, 4P =100

BM100-HS

Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100A

Specification

Thermal magnetic
Standard: IEC60947-2
Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100A
Pole: 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 3P, 4P =50
       lcu(kA) : 4400V (240V) : 3P, 4P =70
       lcu(kA) : 380V : 3P, 4P =85
       lcu(kA) : 220V (240V) : 3P, 4P =125

BM125-SN

Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100, 125A

Specification

Hydraulic magnetic
Standard: IEC60947-2
Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100, 125A
Pole: 2P, 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 2P, 3P, 4P =7.5
       lcu(kA) : 4400V (240V) : 2P, 3P, 4P =15
       lcu(kA) : 380V : 2P, 3P, 4P =22
       lcu(kA) : 220V (240V) : 2P, 3P, 4P =30

BM125-HN

Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100, 125A

Specification

Hydraulic magnetic
Standard: IEC60947-2
Rated current: 10, 15, 20, 30, 40, 50, 60, 75, 100, 125A
Pole: 2P, 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 2P, 3P, 4P =15
       lcu(kA) : 4400V (240V) : 2P, 3P, 4P =25
       lcu(kA) : 380V : 2P, 3P, 4P =30
       lcu(kA) : 220V (240V) : 2P, 3P, 4P =50

BM160-SN

Rated current: 125, 140, 160A

Specification

Adj. thermal / Fixed magnetic
Standard: IEC60947-2
Rated current: 125, 140, 160A
Pole: 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 2P, 3P, 4P =15
       lcu(kA) : 4400V (240V) : 2P, 3P, 4P =25
       lcu(kA) : 380V : 2P, 3P, 4P =30
       lcu(kA) : 220V (240V) : 2P, 3P, 4P =50

BM160-HN

Rated current: 125, 140, 160A

Specification

Adj. thermal / Fixed magnetic
Standard: IEC60947-2
Rated current: 125, 140, 160A
Pole: 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 3P, 4P =20
       lcu(kA) : 4400V (240V) : 3P, 4P =32
       lcu(kA) : 380V : 3P, 4P =36
       lcu(kA) : 220V (240V) : 3P, 4P =85

BM160-HฺB

Rated current: 125, 140, 160A

Specification

Thermal magnetic
Standard: IEC60947-2
Rated current: 125, 140, 160A
Pole: 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 3P, 4P =25
       lcu(kA) : 4400V (240V) : 3P, 4P =42
       lcu(kA) : 380V : 3P, 4P =50
       lcu(kA) : 220V (240V) : 3P, 4P =85

BM160-HฺC

Rated current: 125, 140, 160A

Specification

Thermal magnetic
Standard: IEC60947-2
Rated current: 125, 140, 160A
Pole: 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 3P, 4P =42
       lcu(kA) : 4400V (240V) : 3P, 4P =55
       lcu(kA) : 380V : 3P, 4P =70
       lcu(kA) : 220V (240V) : 3P, 4P =100

BM160-HฺS

Rated current: 125, 140, 160A

Specification

Thermal magnetic
Standard: IEC60947-2
Rated current: 125, 140, 160A
Pole: 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 3P, 4P =50
       lcu(kA) : 4400V (240V) : 3P, 4P =70
       lcu(kA) : 380V : 3P, 4P =85
       lcu(kA) : 220V (240V) : 3P, 4P =125

BM250-CN

Rated current: 125, 150, 175, 200, 225, 250A

Specification

Adj. thermal / Fixed magnetic
Standard: IEC60947-2
Rated current: 125, 140, 160A
Pole: 2P, 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 2P, 3P, 4P =7.5
       lcu(kA) : 4400V (240V) : 2P, 3P, 4P =15
       lcu(kA) : 380V : 2P, 3P, 4P =22
       lcu(kA) : 220V (240V) : 2P, 3P, 4P =30

BM250-SN

Rated current: 125, 150, 175, 200, 225, 250A

Specification

Adj. thermal / Fixed magnetic
Standard: IEC60947-2
Rated current: 125, 140, 160A
Pole: 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 2P, 3P, 4P =
       lcu(kA) : 4400V (240V) : 2P, 3P, 4P =
       lcu(kA) : 380V : 2P, 3P, 4P =
       lcu(kA) : 220V (240V) : 2P, 3P, 4P =

BM250-HN

Rated current: 125, 150, 175, 200, 225, 250A

Specification

Adj. thermal / Fixed magnetic
Standard: IEC60947-2
Rated current: 125, 140, 160A
Pole: 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 2P, 3P, 4P =
       lcu(kA) : 4400V (240V) : 2P, 3P, 4P =
       lcu(kA) : 380V : 2P, 3P, 4P =
       lcu(kA) : 220V (240V) : 2P, 3P, 4P =

BM250-HB

Rated current: 125, 150, 175, 200, 225, 250A

Specification

Adj. thermal / Fixed magnetic
Standard: IEC60947-2
Rated current: 125, 140, 160A
Pole: 3P, 4P

Breaking Capacity

Model : (Ics = 50%Icu)
       lcu(kA) : 500V : 2P, 3P, 4P = 25
       lcu(kA) : 4400V (240V) : 2P, 3P, 4P = 42
       lcu(kA) : 380V : 2P, 3P, 4P = 50
       lcu(kA) : 220V (240V) : 2P, 3P, 4P = 85